Contact Infrared Thermometer - Digital Thermometer
- A dual-mode infrared thermometer, BPL Accudigit IR-D2 measures temperature from the forehead or the ear.
- It can display the temperature in both Fahrenheit/Degree Celsius. With the capability to store 10 memories, Accudigit is a must-have at home.
Features
- Forehead, Eardrum and object modes enables quick detection of body temperature and object temperature
- Equipped with high sensitive infrared sensor, which provides accurate & consistent readings
- Comes with user selectable two temperature measurement units - °F and °C
- Fever alarm indicates if temperature exceeds the higher limit
- Automatic memory function records the last 10 measurements
Multiple Operating Modes:
Forehead, Eardrum and object modes enables quick detection of body temperature and object temperature
Clinical Accuracy:
Equipped with high sensitive infrared sensor, which provides accurate & consistent readings
Fever Alarm:
Fever alarm indicates if temperature exceeds the higher limit
Auto Shut Off
Shuts down the device when idle for 2 minutes, thereby extending the battery life
Selectable °F and °C
Comes with user selectable two temperature measurement units - °F and °C
Low Battery Indication
Visually indicates when the battery has been discharged below a specific level
Fast Measurement
Acquires temperature readings within 1 second
Memory
The automatic memory function records the last 10 measurements
Product Specifications
|
Description
|
Dual Mode Infrared Thermometer
|
Model
|
BPL Accudigit IR-D2
|
Display
|
LCD digital display
|
Measurement Range
|
Ear/Forehead mode : 34.0°C to 43.0°C(93.2°F to 109.4°F)
Object mode : 0°C to 100°C (32°F to 212°F)
|
Operation Mode
|
Ear/Forehead/Object modes (Adjustable)
|
Laboratory Accuracy
|
Ear/Forehead mode:
±0.2°C (0.4°F) during 35.5°C to 42.0°C (95.9°F to 107.6°F) at 15°C
to 35°C (59.0°F to 95.0°F) operating temperature range
±0.3°C (0.5°F) for other measuring & operating temperature range
Object mode: ±4% or ±2°C(±4°F) whichever is greater
|
Display Resolution
|
0.1°C or 0.1°F
|
Measurement Time
|
Ear mode/Object mode: Approx. 1 second
Forehead: Approx. 3 seconds
|
Power Source
|
DC3V (2 X AAA alkaline batteries)
|
Operating Environment
|
Temperature: 10°C to 40°C(50°F to 104°F),
Humidity: 15% to 85%RH, non- condensing
Atmospheric Pressure : 700hPa to 1060hPa
|
Storage & Transport
Environment
|
Temperature: -25°C to 55°C (-13°F to 131°F),
Humidity: 15% to 95%RH, non-condensing
Atmospheric Pressure : 700hPa to 1060hPa
|
Clinical Accuracy
|
Clinical bias: 0.05°C (0.09°F)
Clinical repeatability: 0.11°C (0.20°F)
Limits of agreement: 1.04°C (1.88°F)
|
Dimension
|
155 x 39 x 50mm
|
Weight
|
Approx. 85g (with batteries)
|
Ingress Protecting Rating
|
IP22
|
|
GST -12%
|